Cable is the cheapest line in the BOM and the most expensive to change later. The choice comes down to four questions: how far, how much bandwidth, how much PoE current, and what the environment does to the jacket. Answer those and the category picks itself.
| Cable | Rated speed | Max channel | PoE suitability | Typical use here |
|---|---|---|---|---|
| Cat5e | 1G | 100 m | adequate for af / at | indoor camera drops, short cabinets |
| Cat6 | 1G to 100 m, 10G to ~55 m | 100 m | better heat and loss behaviour | default for new camera projects |
| Cat6A | 10G to 100 m | 100 m | best, heavier and stiffer | 10G uplinks, dense PoE cabinets |
| Fiber (OS2 / OM3-4) | 10G+ to km | km | not applicable | building-to-building, runs over 100 m |
Cat5e is not obsolete for cameras — 4MP H.265 streams fit easily in 1G. What Cat5e loses is margin: on a 100 m PoE run at 30 W it dissipates more heat in the bundle and has less headroom for a poorly terminated connector. On new installations Cat6 costs little more and removes both worries.
Copper-clad aluminium looks like copper, tests like copper on a continuity checker, and fails on PoE. Aluminium has roughly 60% more resistance, so the same run drops more voltage and heats more. Cameras brown out at night, PTZs reboot when they pan, and the installer blames the switch.
100 m is a hard channel limit, not a guideline, and it includes patch panels and bends in the path. Beyond that — or between buildings, where earth potential differs — fiber is the correct engineering answer, not an upgrade.
For a run that is long but not building-to-building, our note on long camera runs compares extenders and converters in more detail.
| Situation | Cable |
|---|---|
| Indoor camera drop, under 60 m, af/at | Cat5e solid copper is fine; Cat6 preferred |
| New build, any PoE, up to 100 m | Cat6 solid copper |
| 10G uplink or dense PoE cabinet | Cat6A |
| Over 100 m, or building to building | Fiber with converters or SFP uplinks |
| Anywhere a cheap reel is tempting | check for CCA before it goes in |
Send the run lengths and camera models and we will confirm which port standard and uplink you need at each cabinet. Ask for a quote.
Yes. Cat5e carries 802.3af and 802.3at fine within 100 m. It has less thermal and voltage headroom than Cat6, so it is a poor choice for long 30 W runs or dense cabinets.
Cut a single strand. Copper is copper-coloured and bends; aluminium is white, lighter and snaps. Reel labels also state CCA or copper clad — treat those as a rejection.
Only when distance or electrical isolation demands it. Fiber carries no power, so cameras still need local power or a PoE switch at the far end.
No. Cable does not change image quality. It changes error rates, voltage drop and the reliability of the link — which is what makes a camera look unreliable.